A search for a TRIAC dimmer soft-start lands on one parenthetical in the BL-TRIAC function note: there is a soft-start at power-up. The electrical table has no ramp time, no slope, and no milliseconds. The default log law, the 0–100% PWM duty, and the 1 kHz / 10 kHz / 16 kHz carriers do not convert into a rise time.

BL-TRIAC is a project-based TRIAC dimming module from Jarwey, not a catalog SKU. If the power-up has to look a certain way, send that requirement; Jarwey does the design, the proposal, and the delivery. Leading-edge and trailing-edge wiring is a separate note. The log-curve note already records that the sheet gives no soft-start milliseconds. That table stays there.

Where the sheet actually mentions it

The middle column of the electrical table is the sheet’s standard column, not a lab typical measured later.

Place in the noteWhat it saysStop here
Function noteSoft-start at power-upPresence only. No milliseconds, no slope
Electrical rowsSupply 12 V min, 15 V standard, 30 V max; current standard 5 mA, max 10 mA (min blank); PWM duty 0% to 100%No ramp-time row. Duty endpoints are not a rise time
Dimming lawLogarithmic by default, customizableSteady brightness law, not the power-up interval
Signal pathRC filter, op-amp conditioning, MCU AD, dimming law, then PWM, for deep dimmingThe path does not assign the soft-start to one block. Do not assign it

The three PWM rows are carriers

Load rowResistorPWM frequencyNot a ramp
Magnetic track, TRIAC out, constant voltageR18 = 10 kΩ10 kHzCarrier. Not the power-up rise
LED strip, TRIAC out, constant voltageR19 = 10 kΩ16 kHzSame reading. Equal 10 kΩ parts do not imply equal soft-start
Fixture, TRIAC out, constant currentResistor not stated1 kHz1 kHz is not a one-second ramp. Do not invent the resistor

How to pick the row is in the frequency note. High-side PWM on pin 6 versus DIMIN/PWM OUT on pin 9 is in the pin note. The 12 V / 15 V / 30 V window is in the aux-rail note. Moving that rail does not fill in a millisecond.

A defined rise is a project line

Custom. The sheet says the module can be customized, and that firmware can be changed for a non-standard dimming function. The soft-start note is not a menu of times. If the job accepts “soft-start at power-up, time not stated,” write that acceptance on the sample form. If the job needs a defined power-up, send the requirement. Do not type a millisecond into the sheet. What else the brief has to lock is in the custom-module note.

Cost. This sentence is a module note, not a timer printed on an imported wall control. Lutron QSGR-3P (leading edge), Schneider L5504D2A (leading edge), Siemens 5UH82223-NC01 and 5WG1 528-1D801, Panasonic WMY549, Legrand VRCM2, and Opple P068102 (leading edge) are controls the sheet lists for evaluation. They need a joint check. They are not a drop-in replacement. How a system quote splits is in the cost note.

Delivery. Samples, small lots, and the date follow the project. The sample line has to say whether power-up stays as written or is a design change. The sheet has no day count and no minimum order. How the date is tracked is in the small-batch note.

Checklist before power-up is specified

  1. Which sentence: soft-start exists only as the function note. The electrical table has no such row.
  2. No added milliseconds: the sheet does not state a time. Do not copy one from a wall-control datasheet.
  3. Separate from the log law: logarithmic is the dimming curve, and it can be customized. It is not the power-up interval.
  4. Separate from the carrier: 10 kHz track, 16 kHz strip, 1 kHz constant-current fixture. 1 kHz is not a one-second ramp. The constant-current row states no resistor.
  5. Separate from duty: PWM duty runs from 0% to 100%. The ends are not a rise time.
  6. Separate from the rail: 12 V minimum, 15 V standard, 30 V maximum; current 5 mA standard, 10 mA maximum. Do not define the ramp by moving the rail.
  7. Sample: accept the note as written, or file the power-up as a custom line, then build the sample. Request the datasheet from Jarwey. A panel check is required before a small lot.

Product page and the note

Send the load (strip, magnetic track, or fixture) and whether power-up stays as written or must change: kerry.w@jarwey.cn · contact. Design, a joint check, samples, and the date follow that line.